Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
ImplantNewsPerio ; 3(3): 506-516, mai.-jun. 2018. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-905516

RESUMO

Objetivos: melhorar a percepção do dentista sobre a atratividade do sorriso através de avaliações objetivas. Material e métodos: fotografias frontais de sorrisos (envolvendo a área dos caninos) foram aleatoriamente escolhidas e dispostas em dois sentidos verticais variados (nivelado, abaixo) numa guia personalizada contendo quatro molduras labiais do sorriso (fino, médio, grosso, invertido). Os aspectos que influenciam a atratividade do sorriso (PD = proporção dentária, PV = posicionamento vertical dentário, EL = espessura labial, FG = festonamento gengival) também foram incluídos e uma nota final geral atribuída ao sorriso geral (SG). Adicionalmente, o formulário do exercício continha a opção "existe um implante?" e "qual sua localização?". Todos os itens foram avaliados através de escalas de Likert. A prevalência de respostas foi calculada para cada item. O teste de Wilcoxon (alfa = 5%) foi usado para verificar a possibilidade de diferença de opinião entre os nivelamentos horizontais e para uma mesma moldura de sorriso. Os níveis de confiabilidade (concordância absoluta = ICC e responsividade = Cronbach alfa) também foram avaliados. Resultados: um teste-piloto foi conduzido com 16 estudantes. Trinta e duas combinações foto/moldura labial foram geradas e apresentadas de forma randomizada. A avaliação geral do sorriso ficou em: pobre (11/32), mediano (6/32), bom (15/32) e muito bom (1/32). O número de acertos da possível posição do implante foi 13 em 32 tentativas. Diferenças estatisticamente significativas entre os nivelamentos foram observadas nas situações 1/17 (p=0,0001), 13/29 (p=0,02), 2/18 (p=0,0002), 6/22 (p=0,0001), 14/30 (p=0,0001), 7/23 (p=0,01) e 15/31 (p=0,039). Os maiores coeficientes de ICC e Cronbach alfa foram vistos para o sorriso geral e FG. Conclusão: a percepção visual do dentista pode ser treinada mudando-se a moldura labial e o nivelamento vertical dos dentes e é influenciada pelo festonamento gengival. O teste se mostrou útil na verificação da atratividade do sorriso.


Objectives: to improve the perception of the dentist on the smile attractiveness through objective evaluations. Material and methods: frontal photographs of smiles (involving the canine area) were randomly chosen and arranged in two different vertical directions (leveled, below) in a personalized guide containing four lip architectures (thin, medium, thick, inverted). The aspects that infl uence the smile attractiveness (PD = dental proportion, PV = vertical tooth position, EL = lip thickness, GS = gingival scalloping) were also included and a general final score attributed to the general smile (SA). Additionally, the exercise form contained questions such as "is there an implant?" and "what is your location?". All items were assessed using Likert scales. The prevalence of responses was calculated for each item. The Wilcoxon test was used to verify the possibility of differences between the horizontal leveling for the same smile architecture. The reliability levels (absolute agreement = ICC and responsiveness = Cronbach alpha) were also evaluated. Results: a pilot test was conducted with 16 students. Thirty-two photos/lip architecture combinations were generated and presented at random. The overall smile rating was: poor (11/32), average (6/32), good (15/32), and very good (1/32). The number of positive responses for implant position was 13 in 32 trials. Statistically significant differences were observed in the combinations 1/17 (p=0.0001), 13/29 (p=0.02), 2/18 (p=0.0002), 6/22 (p=0.0001), 14/30 (p=0.0001), 7/23 (p=0.01) and 15/31 (p=0.039). The highest ICC and Cronbach alpha values were seen for the general smile attractiveness (SA) and GS. Conclusion: the visual perception can be trained by changing the lip architecture and vertical leveling of the teeth and is influenced by gingival scalloping. This test proved to be useful in verifying the smile attractiveness.


Assuntos
Humanos , Prótese Dentária Fixada por Implante , Estética Dentária , Fotografia Dentária , Sorriso , Tecnologia Odontológica
2.
ImplantNewsPerio ; 2(4): 619-626, jul.-ago. 2017. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-859995

RESUMO

Objetivo: familiarizar o leitor com a metodologia estatística da metanálise e mostrar como ler e interpretar o forest plot nas decisões clínicas. Material e métodos: um conjunto fictício de dez estudos com acompanhamento de cinco anos, envolvendo perda óssea comparada para implantes rugosos e lisos, foi simulado. Os parâmetros para metanálise foram obtidos e explicados em detalhes em três situações: 1) usando estes dez estudos; 2) removendo o estudo com a maior amostra; e 3) reduzindo a amostra do maior estudo, comparando-se nos modelos fixo e random. Resultados: na situação 1, o efeito fixo favoreceu os implantes lisos, o efeito random favoreceu os implantes rugosos, mas o valor p não mostrou significado estatístico para cada efeito. Na situação 2, ambos os modelos passaram a favorecer os implantes rugosos, com valores p estatisticamente significativos. Na situação 3, o peso fixo da maior amostra caiu pela metade, e o gráfico forest pilot favoreceu os implantes rugosos nos modelos fixo e random, porém, a diferença estatística só foi significativa no modelo fixo (p=0,000). Conclusão: 1) a criação de modelos fictícios e situações favorece o ensino da leitura da metanálise; 2) mesmo no exemplo fictício, a adoção do modelo random effects trouxe melhor ponderação entre os pesos dos estudos; 3) a decisão clínica de quem lê está influenciada também pela decisão de quais estudos são incluídos, suas amostras e como traduzir a diferença entre as perdas ósseas em benefício clínico.


Objective: to familiarize the reader with the statistical methodology of a meta-analysis and to show how to read and interpret the forest plot for clinical decisions. Material and methods: a hypothetical model with 10 studies over 5 years involving bone loss on rough and machined dental implants was simulated. The parameters of meta-analysis were obtained and explained in three hypothetical scenarios: 1) all 10 studies; 2) removing the study with the larger sample; and 3) using only half of the sample in the larger study, considering the fixed and random effects model. Results: for situation 1, the fixed effect favors the machined implants, while the random effect favors the rough ones, but the p-value did not provide statistical significance for each summary effect. In situation 2, both models favor the rough implants, with statistically significant p-values. For situation 3, the relative weight of the larger sample size was reduced by half, and the forest plot favored the rough implants for both fi xed and random options; however, a statistical difference was only seen at the fixed effects model (P=0.000). Conclusion: 1) the creation of diverse scenarios favors the teaching on how to read a meta-analysis; 2) even thus, the adoption of a random-effect model balanced the weights among studies; 3) the clinical decision of the reader is also infl uenced by which studies were selected, their samples, and how to translate the difference between bone loss into clinical benefits.


Assuntos
Humanos , Perda do Osso Alveolar , Metanálise , Modelos Educacionais , Pesos e Medidas/instrumentação
3.
ImplantNewsPerio ; 2(2): 242-246, mar.-abr. 2017.
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-847146

RESUMO

Este artigo apresenta os achados mais recentes sobre a perda dentária, declínio cognitivo e o possível papel que a mastigação teria na prevenção deste problema mundial. A ausência de dentição funcional afeta » dos adultos no Brasil. Existem evidências anatômicas demonstrando a ligação neuronal entre os circuitos mastigatórios trigeminais e o hipocampo ­ área cerebral da cognição (memória, aprendizado) e primariamente afetada pela doença de Alzheimer. A eficiência manual é significativamente melhorada, quando feita simultaneamente à mastigação. Três estudos com populações humanas significativas mostraram que a deficiência cognitiva é aumentada pelas próteses mal adaptadas; a perda de 16 unidades dentárias é suficiente para ser associada ao impedimento cognitivo severo; e um tempo de edentulismo superior ou acima de 15 anos piora significativamente os escores de cognição. Um estudo mostra que o desenho das PPRs com e sem extensão distal gera atividades cerebrais diferentes, que podem reduzir a habilidade mastigatória. Como os experimentos em animais têm mostrado que a mastigação induz a neurogênese no hipocampo, que este fenômeno pode ser impedido pela troca de uma dieta sólida por uma dieta pastosa, e ainda que o exercício físico em idosos aumenta a área do hipocampo e a percepção espacial, por semelhança, a mastigação cada vez mais se consolidaria como o "exercício principal adicional mais simples" na manutenção dos níveis de cognição. Neste sentido, os profissionais da Odontologia que detectarem a necessidade de colocar adequadamente implantes e próteses o mais cedo possível tornarão seus pacientes edêntulos grandes mind trainers e, possivelmente, estarão contribuindo para reduzir esta patologia de um grande impacto mundial.


This article presents the most recent findings on tooth loss, cognitive decline, and the possible role of mastication to prevent this global problem. The lack of functional dentition affects over » of Brazilian adults. There are anatomical evidences demonstrating the neuronal circuitry relationship among the trigeminal and hippocampus pathways (the cerebral region responsible for long-term memory and learning, being affect by Alzheimer disease). Manual dexterity is significantly improved when combined with masticatory exercise. Three studies with large samples highlightened that cognitive impairment increases for those with maladjusted dentures; sixteen dental lost units are enough for severe cognitive deficit, and that people edentulous for more than 15 years had their cognition scores significantly reduced. Also, one study demonstrated that the partial removable prosthesis design (with and without distal extensions) modify brain activity that can influence on masticatory ability. Animal experiments have shown that masticatory leads to neurogenesis at the hippocampus, and that this phenomenon can be prevented and reversed by alternating hard-and soft-diets. In a similar way, since physical exercise in old persons increases the hippocampal area and spatial perception, mastication could have a more and more evolving paper as "the most simple supplementary exercise" to maintain cognition levels. In this sense, dental professionals detecting the need to and who adequately deliver dental implants and prostheses as soon as possible will turn their edentulous patients into great "mind trainers" and surely would be contributing to reduce the burden of this global disease.


Assuntos
Humanos , Doença de Alzheimer , Cognição/fisiologia , Disfunção Cognitiva , Implantes Dentários , Hipocampo , Mastigação/fisiologia
4.
Clin Implant Dent Relat Res ; 19(1): 123-130, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27189627

RESUMO

PURPOSE: The present study aimed to measure the implant stability quotient (ISQ) values at three different time points after surgical procedures and crestal bone behavior in multiple implants (two or more) installed simultaneously with the bone splitting technique. MATERIALS AND METHODS: For this study, 45 patients with different edentulous areas in the maxilla were selected, and a total of 114 dental implants were installed. Implant stability was measured by resonance frequency analysis immediately following implant placement to assess immediate stability (time 1) and stability at 90 days (time 2), and 150 days (time 3). Crestal bone height was measured in peri-apical radiographs at 90 and 150 days after implantation in relation to each implant shoulder, given that the implants were installed at the level of the crestal bone. RESULTS: Six implants were not osseointegrated. Overall, the means and standard deviations of the ISQ values were 60.3 ± 4.94 (95% confidence interval [CI], 44-69) at baseline, 66.6 ± 5.28 (95% CI, 49-75) at 90 days, and 72.1 ± 4.28 (95% CI, 59-79) at 150 days (p < 0.0001). The mean marginal bone loss of the implants was 1.11 ± 0.61 mm on the mesial side and 1.17 ± 0.61 mm on the distal side at time 2, and 1.73 ± 0.68 mm on the mesial side and 1.79 ± 0.70 mm on the distal side at time 3. A strong positive correlation between implant stability and bone loss was detected (p < 0.0001). CONCLUSIONS: Within the limits of this study, the bone splitting technique with simultaneous implant installation exhibited a good success rate with respect to the osseointegration index but requires attention with respect to crestal bone behavior.


Assuntos
Implantação Dentária Endóssea/métodos , Planejamento de Prótese Dentária , Retenção em Prótese Dentária , Osteotomia Maxilar/métodos , Osseointegração/fisiologia , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Adulto , Projeto do Implante Dentário-Pivô , Feminino , Seguimentos , Humanos , Carga Imediata em Implante Dentário , Masculino , Maxila/diagnóstico por imagem , Maxila/cirurgia , Pessoa de Meia-Idade , Boca Edêntula/diagnóstico por imagem , Boca Edêntula/cirurgia , Análise de Frequência de Ressonância
5.
ImplantNewsPerio ; 1(7): 1322-1326, out.-nov. 2016. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-847945

RESUMO

Alterações nos tecidos moles, na zona estética, podem ocorrer por procedimentos restauradores associados ou não à Implantodontia. Os autores propuseram um dispositivo acrílico simples associado a uma sonda periodontal, para verificação destes níveis em todos os momentos do tratamento reabilitador. O dispositivo em questão também pode ser desenhado e confeccionado em qualquer sistema CAD/CAM.


Soft tissue changes in the esthetic zone can occur after restorative procedures associated or not to implant dentistry. The authors describe a simple acrylic device associated to a periodontal probe to verify those levels during all treatment procedure steps. Also, this device can be design and milled at any CAD/CAM system.


Assuntos
Humanos , Resinas Acrílicas/química , Resinas Acrílicas/uso terapêutico , Desenho Assistido por Computador , Implantes Dentários , Retração Gengival , Terapia de Tecidos Moles
6.
ImplantNewsPerio ; 1(4): 712-721, mai.-jun. 2016. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-847034

RESUMO

Objetivo: avaliar as desadaptações em supraestruturas de implantes e a curva de assinatura torque-ângulo dos parafusos protéticos nas condições monobloco e pós-soldagem. Material e métodos: uma base retangular de aço inox recebeu três implantes de hexágono externo (4,1 mm x 10 mm), onde foram parafusados minipilares de zircônia. Após o enceramento e inclusão, as supraestruturas foram fundidas em monobloco com uma liga de cobalto-cromo, e os cilindros foram numerados sequencialmente (1, 2 e 3). A leitura na interface supraestrutura/pilar foi realizada com um microscópio comparador (precisão de 1 µm), três vezes em cada cilindro. A tensão de torque nos parafusos foi medida com um torquímetro eletrônico odontológico (OsseoCare, Nobel Biocare). Depois, as supraestruturas foram seccionadas e soldadas a plasma (pontos de estabilização) e maçarico (preenchimento da área restante). Novamente, as desadaptações e assinaturas dos parafusos foram avaliadas pela mesma metodologia. Resultados: as médias de desadaptações foram maiores nas supraestruturas em monobloco (C1=3,5 µm; C2=0 µm; C3=31,2 µm) do que nas supraestruturas pós-soldagem (C1=3,0 µm; C2=2,9 µm; C3=18,1 µm). Dentro de cada condição, o teste de Kruskal-Wallis mostrou diferença estatisticamente significativa apenas para o cilindro 3 (monobloco: p < 0,00003 / pós-soldagem: p=0,008) em relação aos cilindros 1 e 2. Uma diferença estatisticamente significante foi encontrada apenas no C3, comparando as condições monobloco e pós-soldagem (teste t pareado, p=0,03). A assinatura dos parafusos se mostrou melhor na condição pós-soldagem. Conclusão: a fundição monobloco gera instabilidade na assinatura dos parafusos. A desadaptação nos parafusos protéticos de supraestruturas sobre minipilares de zircônia melhora após secção e soldagem híbrida.


Objective: to evaluate the misfi t at implant frameworks and the torque-angle signature curves at the prosthetic screws at one-piece and after soldering conditions. Material and methods: a stainless steel rectangular base received 3 external hex implants (4.1 x 10 mm) where zirconia mini-abutments were fastened. After wax-up and investing, the frameworks were one-piece cast with a Co-Cr alloy, and the prosthetic cylinders sequentially identified (1, 2, and 3). The misfit at the framework/abutment interface was measured with a microscope (reading error 1 µm) 3 times for each cylinder. The screw tension was investigated with an electronic torqued device (Osseocare, Nobel Biocare). After, the frameworks were sectioned and soldered with plasma (stabilization points) and gas torch (filling of the remaining areas). Again, the misfit and torque-angle signatures were measured as described. Results: mean misfit values were greater for one-piece castings (C1=3.5 µm; C2=0 µm; C3=31.2 µm) than after soldering (C1=3.0 µm; C2=2.9 µm; C3=18.1 µm). Within each condition, the Kruskal-Wallis test demonstrated a statistically significant difference only for C3 (one-piece casting: p < 0.00003 / after soldering: p=0.008) compared to C1 and C2. Between each condition, a significant difference was seen only for C3 in the one-piece and after soldering conditions (paired t test, p=0.03). The torque-angle signatures demonstrated a better behavior after soldering. Conclusion: one-piece castings provide instability at torque-angle signatures. Thus, the seating of the prosthetic abutments over the zirconia mini-abutments improves after sectioning and hybrid soldering.


Assuntos
Implantes Dentários , Soldagem em Odontologia/efeitos adversos , Ligas Metalo-Cerâmicas/efeitos adversos , Torque , Zircônio
7.
ImplantNewsPerio ; 1(3): 479-489, abr.-mai. 2016. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-847598

RESUMO

Este relato de caso demonstra uma combinação de estratégias de RTG para alívio do defeito residual na zona estética. Um paciente do sexo masculino havia sofrido um acidente traumático no dente 11 durante a infância, com tratamento endodôntico e reimplantação imediata. Dez anos depois, o desnível entre as margens gengivais era de 10 mm, e uma reabsorção radicular estava presente. Para tentar diminuir a recessão de tecido mole e o contorno ósseo deficiente, uma matriz colágena suína (MucoGraft) foi montada no sentido vertical substituindo a parede vestibular, e o alvéolo de extração foi preenchido com osso bovino inorgânico (Bio-Oss). A coroa dentária natural foi usada como pôntico no aparelho ortodôntico de contenção. Três meses depois, e após um exame por tomografia computadorizada feixe cônico para determinação dos níveis ósseos resultantes, o conjunto implante dentário (3,4 mm x 10 mm)/pilar (platformswitching) e osso bovino foi colocado no alvéolo cicatrizado, e a coroa natural foi trocada por uma coroa provisória cimentada. Seis meses depois, um enxerto gengival livre foi aplicado. Após o condicionamento do tecido mole, o desnivelamento gengival entre as margens reduziu-se para 2 mm. A restauração definitiva recebeu infraestrutura em zircônia CAD/CAM recoberta por porcelana feldspática. Mesmo que a estratégia combinada tenha se mostrado útil no alívio da situação clínica, estudos longitudinais com amostras maiores são necessários para comprovar sua eficácia.


This case report demonstrates a combination of RTG strategies to alleviate a residual defect in the esthetic zone. A male patient had suffered a traumatic accident at the tooth 11 during childhood, with endodontic treatment and immediate replantation. Ten years later, the unbalance between the gingival margins was 10 mm, and a root resorption was detected. In an attempt to reduce the soft tissue recession and poor bone contour, a porcine collagen matrix (MucoGraft) was mounted vertically replacing the labial wall, and the alveolar extraction socket fi lled with xenogeneic bovine bone (Bio-Oss). The natural dental crown was used as the pontic in the orthodontic device. Three months later and after a cone beam computerized tomography to determine the resulting bone levels, the dental implant (3.4 mm x 10 mm)/abutment (platform-switching) assembly and bovine bone were placed in the healed socket, and the natural crown was replaced by a cemented temporary crown. Six months later, a free gingival graft was applied. After soft tissue conditioning, the unbalance between gingival margins between was reduced to 2 mm. The final restoration received a CAD/CAM zirconia infrastructure veneered with feldspathic porcelain. Even that the combined strategy has proven useful in this clinical situation. Longitudinal studies with larger samples are needed to confi rm its effectiveness.


Assuntos
Humanos , Masculino , Adulto , Materiais Biocompatíveis , Reabsorção Óssea , Implantes Dentários para Um Único Dente , Regeneração Tecidual Guiada , Cirurgia Bucal/métodos , Extração Dentária
8.
Int J Oral Maxillofac Implants ; 31(1): 111-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26800167

RESUMO

PURPOSE: To verify whether the diversity of systemic medical conditions and smoking act as biologic associated factors for peri-implantitis. MATERIALS AND METHODS: The PICO question was: "In patients with osseointegrated dental implants, does the presence of smoking habits or a compromised medical status influence the occurrence of peri-implantitis compared with the presence of good general health?" Smoking and systemic conditions such as type 2 diabetes mellitus, cardiovascular diseases, rheumatoid arthritis, lung diseases, obesity, cancer, deep depression, and osteoporosis were screened. Selection criteria included at least 10 patients per condition, 1 year of follow-up after implant loading, and strict cutoff levels (probing pocket depth [PPD], bleeding on probing [BOP] and/or pus, marginal bone loss) to define peri-implantitis. RESULTS: From the 1,136 records initially retrieved, 57 were selected after title and abstract analyses. However, only six papers were considered for qualitative evaluation. No randomized controlled clinical trial was found. Smoking was associated with peri-implantitis in only one out of four studies. Poorly controlled type 2 diabetes accentuated only PPD and radiographic marginal bone level prevalence rates in peri-implant patients (one study). Cardiovascular disease was considered a risk (one out of two studies). The chance of peri-implant patients harboring the Epstein-Barr virus was threefold in one report. No associations were found for rheumatoid arthritis. CONCLUSION: Data from existing studies point to smoking and diabetes as biologic associated factors for peri-implantitis. However, the body of evidence is still immature, and the specific contribution of general health problems to peri-implantitis requires additional robust epidemiologic and clinical investigations.


Assuntos
Doença Crônica/epidemiologia , Peri-Implantite/epidemiologia , Fumar/epidemiologia , Implantes Dentários , Diabetes Mellitus Tipo 2/epidemiologia , Humanos , Prevalência , Fatores de Risco
9.
Clin Oral Implants Res ; 27(5): 577-82, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26037595

RESUMO

OBJECTIVES: The present study measured implant stability quotient (ISQ) values at three different time points after surgical procedures to compare whether the stability values differed between implants placed in fresh extraction sockets versus healed alveolar sites. MATERIALS AND METHODS: To measure implant stability, resonance frequency analysis (RFA) was performed in 77 patients (53 women, 24 men) with a total of 120 dental implants. These implants were divided into two groups: Group 1 included 60 implants in healed alveolar sites (22 in the maxilla, 38 in the mandible), and Group 2 included 60 implants in fresh sockets (41 in the maxilla, 19 in the mandible). Implant stability was measured immediately at implant placement (baseline), 90, and 150 days later. Statistical analysis was made using a multivariate regression linear model at implant level (α = 0.05). RESULTS: Overall, the means and standard deviations of the ISQ values were 62.7 ± 7.14 (95% confidence interval [CI], 39-88) at baseline, 70.0 ± 6.22 (95% CI, 46-88) at 90 days, and 73.4 ± 5.84 (95% CI, 58-88) at 150 days. In Group 1, the ISQs ranged between 64.3 ± 6.20 and 75.0 ± 5.69, while in Group 2, presented lower values that ranged between 61.2 ± 8.09 and 71.9 ± 5.99 (P = 0.002). Anatomic location and times periods were the only identified variables with an influence on ISQ values at implant level (P < 0.0001). CONCLUSIONS: The stabilities of the implants placed in the fresh sockets and in healed sites exhibited similar evolutions in ISQ values and thus osseointegration; however, the implants in the healed alveolar sites exhibited superior values at all time points.


Assuntos
Processo Alveolar/cirurgia , Implantes Dentários , Osseointegração , Alvéolo Dental/cirurgia , Feminino , Humanos , Masculino , Mandíbula/cirurgia , Maxila/cirurgia
10.
Int J Oral Maxillofac Implants ; 30(4): 834-42, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26252036

RESUMO

PURPOSE: To compare implants in healthy conditions and implants with peri-implantitis with regard to their clinical parameters and the microbiologic composition at the peri-implant sulcus, inside the implant connection, and the gingival sulcus of neighboring teeth. MATERIALS AND METHODS: A cross-sectional study was performed including consecutive patients with implants in healthy conditions and with peri-implantitis. Clinical parameters for which patients were screened included bleeding on probing, pocket depth, and plaque index at six sites. Samples for microbiologic analysis were obtained from three locations: the peri-implant sulcus, inside the implant connection, and the gingival sulcus of neighboring teeth. Quantitative real-time polymerase chain reaction (PCR) was carried out for total counts of 10 microorganisms: Aggregatibacter actinomycetemcomitans, Porphyromona gingivalis, Tanerella forsythia, Tanerella denticola, Prevotela intermedia, Peptostreptococcus micros, Fusobacterium nucleatum, Campylobacter rectus, Eikenella corrodens, and Candida albicans. The response variables were the percentage of positive sites and total bacterial counts. RESULTS: One hundred twenty-two implants in 57 patients were analyzed in the healthy group and 113 implants in 53 patients in the peri-implantitis group. Differences between the groups were statistically significant for bruxism, probing pocket depth, bleeding on probing, and radiographic bone level. Orange complex species (P intermedia, P micros, F nucleatum) were the most prevalent in the three types of sites for both groups, and prevalence values were higher in the peri-implantitis group. Differences in prevalence between groups were more marked inside the connection than in the peri-implant sulcus. Absolute loads of most microbes and total bacterial counts were higher for the peri-implantitis group in the three locations. Again, differences were bigger inside the connection than at the peri-implant sulcus. Significant interactions were found for prevalence and absolute microbial loads between groups and locations, and for the interaction of group × location. CONCLUSION: Clinical and microbiologic differences were observed between healthy subjects and those with peri-implantitis. Microbiologic differences between groups were more marked inside the connection than in the peri-implant sulcus. The potential role of the implant connection as a microbial reservoir for peri-implant diseases and in the outcome of their treatment should be confirmed with further studies.


Assuntos
Implantes Dentários/microbiologia , Gengiva/microbiologia , Peri-Implantite/microbiologia , Idoso , Aggregatibacter actinomycetemcomitans/isolamento & purificação , Processo Alveolar/diagnóstico por imagem , Carga Bacteriana , Bacteroides/isolamento & purificação , Interface Osso-Implante/diagnóstico por imagem , Bruxismo/complicações , Campylobacter rectus/isolamento & purificação , Candida albicans/isolamento & purificação , Estudos Transversais , Índice de Placa Dentária , Eikenella corrodens/isolamento & purificação , Feminino , Fusobacterium nucleatum/isolamento & purificação , Gengiva/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Peptostreptococcus/isolamento & purificação , Peri-Implantite/patologia , Índice Periodontal , Bolsa Periodontal/microbiologia , Bolsa Periodontal/patologia , Porphyromonas gingivalis/isolamento & purificação , Prevotella intermedia/isolamento & purificação , Radiografia , Treponema denticola/isolamento & purificação
11.
Int J Oral Maxillofac Implants ; 30(3): 583-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26009909

RESUMO

PURPOSE: To verify whether the parts of dental implants can be contaminated by opportunistic pathogens. MATERIALS AND METHODS: In this cross-sectional study, 38 individuals (52 implants) were investigated. Samples for microbiologic analysis (for a total of 180 sites) were obtained from each individual, from three types of sites in the following order: (1) the peri-implant sulcus of each implant, (2) the gingival sulcus of adjacent teeth, and (3) inside the implant-abutment connection and the abutment of each implant. Swabs from the oral mucosa (cheeks, tongue, and pharynx) were also collected. Quantitative real-time polymerase chain reaction was carried out for total bacterial counts of Enterococcus faecalis and Pseudomonas aeruginosa. Two-way analysis of variance (sites, species) and Holm-Sidak tests were used for statistical analyses. RESULTS: No opportunistic bacteria were found in the gingival sulcus specimens (38 sites). E faecalis was detected in the peri-implant sulcus (3 of 52 sites) and the inner connection/abutment portion (3 of 52 sites). P aeruginosa was identified only in the oral mucosa swabs (1 of 38 sites) and represented the highest bacterial number (3.5 × 106). Statistically significant differences were only found between species and in the peri-implant sulcus. CONCLUSION: Within the limitations of this study, significant differences in the presence and levels of nosocomial bacteria were detected in the peri-implant environment of diseased implants. From a clinical point of view, data from this study might suggest that, in patients affected by peri-implantitis, prostheses should be removed and the implant-abutment connection disinfected routinely, along with implant surface decontamination.


Assuntos
Implantes Dentários/microbiologia , Enterococcus faecalis/isolamento & purificação , Peri-Implantite/microbiologia , Pseudomonas aeruginosa/isolamento & purificação , Idoso , Carga Bacteriana , Infecção Hospitalar , Estudos Transversais , Feminino , Gengiva/microbiologia , Humanos , Masculino , Pessoa de Meia-Idade , Mucosa Bucal/microbiologia , Reação em Cadeia da Polimerase em Tempo Real , Tamanho da Amostra , Temperatura
12.
PróteseNews ; 1(3): 328-333, out.-dez. 2014. ilus
Artigo em Português | BBO - Odontologia | ID: biblio-853939

RESUMO

A prática clínica fornece ao protesista um nível de conhecimento interminável. Entretanto, na comunicação com o laboratório, alguns ruídos podem ocorrer. Para diminuir os contratempos, dois aspectos são importantes: 1) a criação de um banco de dados de formas dentárias naturais a partir dos aspectos vestibular e incisal na região dos dentes anteriores superiores, que pode ser transmitido e compartilhado digitalmente; 2) o uso mandatório do arco facial para montagem dos modelos no articulador semiajustável, revelando as diferenças entre o que se vê na clínica e as perspectivas laboratoriais para confecção das restaurações provisórias ou definitivas.


Assuntos
Humanos , Desenho Assistido por Computador , Prótese Dentária , Planejamento de Prótese Dentária , Prótese Parcial Fixa , Aparelhos de Tração Extrabucal , Reabilitação Bucal
13.
ImplantNews ; 11(6a): 140-146, 2014. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-733633

RESUMO

Objetivo: avaliar a resistência à fratura de três modelos de implantes cônicos com design semelhante, porém, com diferentes conexões protéticas e diâmetros, simulando três níveis de perda óssea. Material e métodos: noventa implantes de 13 mm de comprimento foram divididos em 18 grupos de cinco amostras cada, combinando-se a conexão (HE, HI, CM), o diâmetro (3,5 mm; 4,0 mm) e a profundidade de inserção (0, 3 e 5 mm). Os conjuntos foram incluídos em resina epóxica e submetidos à carga compressiva com inclinação de 30º em relação ao seu eixo longitudinal e o momento da força (N.mm) obtido. A análise estatística foi realizada com os testes Anova - 3 critérios e Holm-Sidak para comparações múltiplas (α=0,05). Resultados: diferenças significativas foram observadas para as interações: conexão x diâmetro, conexão x profundidade de inserção; e diâmetro x profundidade de inserção, todas p < 0.001. O maior momento de força médio foi observado no grupo HI (diâmetro 4 mm, inserção zero: 2689 N.mm) e o menor para o grupo HE (diâmetro 3,5 mm, inserção 5 mm: 907,52 N.mm). A conexão HE, dentro de cada diâmetro testado, não mostra redução significativa de resistência entre as profundidades 3 mm e 5 mm. A conexão CM foi a única a não apresentar diferença entre os diâmetros 3,5 mm e 4,0 mm para os valores de resistência à fratura entre os diferentes níveis de inserção. As menores reduções entre os momentos de força foram observadas no grupo CM. Conclusão: implantes sem inserção óssea com valores maiores do que 3 mm apresentam uma diminuição bastante significativa nos valores de resistência à fratura. Uma perda óssea de até 5 mm pouco afeta a conexão CM, o que não ocorre para as conexões HE e HI.


Assuntos
Implantes Dentários , Perda da Inserção Periodontal
14.
ImplantNews ; 10(6a): 52-58, 2013. tab
Artigo em Português | LILACS | ID: lil-761262

RESUMO

Verificar a perda óssea radiográfica ao redor dos implantes de largo diâmetro quando implantes de diâmetro estreito/convencional são usados no mesmo estudo. Métodos: uma busca eletrônica feita entre os anos de 1966 e 2012 no PubMed/Medline, combinando as palavras-chave dental implants, wide diameter, wide body, large platform, large diameter e wide platform, foi realizada. Na primeira fase, 486 artigos foram recuperados para análise preliminar do título e dos resumos até 1º de março de 2012. Na segunda fase (60 artigos), estudos laboratoriais, modelos animais, estudos de casos e séries de casos com menos de um ano de acompanhamento foram excluídos. O desfecho primário foi a mensuração da perda óssea radiográfica. Resultados: sete estudos (dois prospectivos, dois RCT prospectivos, três retrospectivos) foram selecionados. Os diâmetros dos implantes variaram de 3,5 mm a 8,0 mm. Em geral, os valores de perda óssea para os implantes estreitos/convencionais e de largo diâmetro foram menores do que 2,0 mm, tanto nos estudos prospectivos (faixa um/três anos) como nos retrospectivos (faixa um/seis anos). Dois estudos retrospectivos atribuíram as diferenças observadas às curvas de aprendizagem e desenhos dos implantes. Ainda, dois estudos prospectivos demonstraram os benefícios dos protocolos plataforma switching (4,1/5,0 mm) na redução da perda óssea pelo menos um ano depois. Um RCT não demonstrou diferenças significativas (um ano de acompanhamento; implantes de 8 mm versus implantes de 4 mm de diâmetro). A maioria dos implantes foi inserida com protocolo de dois estágios e em sítios já cicatrizados. Conclusão: dentro dos limites desta revisão, a perda óssea radiográfica ao redor dos implantes de largo diâmetro não difere dos implantes estreitos/convencionais, quando comparada para a mesma população de pacientes...


To verify radiographic bone loss levels around wide-body dental implants when narrow/or standard ones are used in the same study. Methods: an electronic search between the years of 1966 to 2012 was made on the PubMed/Medline database combining the keywords “dental implants”, “diameters”, “wide diameter”, “wide body”, “large platform”, “large diameter”, and “wide platform”. In the first phase, four-hundred and eight-six articles were retrieved for preliminary title and abstract analyses until March 1st, 2012. In the second phase (60 articles), no laboratory, animal, case studies, or clinical studies with less than one-year of follow-up were included. The primary outcome was radiographic bone loss measurement. Results: seven studies (two prospective, two prospective RCTs, three retrospective) were selected. Implant diameters varied from 3.5 mm to 8.0 mm. Overall mean bone loss values for narrow/standard and wide diameters were less than 2.0 mm in both prospective (range: 1-3 years) and retrospective (range: 1-6 years) trials. Two retrospective studies attributed the observed differences due to learning curves and implant designs. Also, two prospective studies demonstrated the benefi ts of platform switching protocols (4.1/5.0 mm) in reducing bone loss at least one year later. One RCT demonstrated no significant differences (1 year of follow-up; 8 mm - versus 4 mm - diameter fi xtures). Most implants were inserted with a two-stage technique and at healed sites. Conclusions: within the limits of this review, radiographic bone loss around wide diameter implant does not differ from narrow/standard diameters in the same patient population...


Assuntos
Humanos , Perda do Osso Alveolar , Implantes Dentários
15.
ImplantNews ; 10(6): 731-733, 2013. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-707606

RESUMO

A comunicação bem-sucedida entre pacientes e clínicos na terapia de suporte aos implantes pode ser comprometida por diversas razões. O objetivo deste trabalho foi apresentar uma nova ferramenta educacional de conhecimento, como o diagrama de motivação por cores (DMC). Com base em uma radiografia periapical feita pela técnica do paralelismo e cone longo, os clínicos podem determinar se os níveis ósseos do paciente estão acima ou abaixo da plataforma do implante. Cálculos simples são feitos entre os anos consecutivos para se determinar o remodelamento ósseo. Depois, o limiar de perda é atribuído para cada intervalo e um código de cores (azul, amarelo, verde ou vermelho) é aplicado. Desta forma, o paciente pode se concentrar nos significados das cores e ter compreensão total dos resultados, além de melhorar sua higiene oral caseira. Embora a validade desta ferramenta ainda não tenha sido investigada cientificamente, ela lança novas perspectivas sobre a motivação do paciente no tratamento com implantes osseointegrados.


Successful communication between patients and clinicians during implant supportive therapy can be compromised due to several reasons. The aim of this paper is to present a new educational tool known as the color motivation chart (CMC). Based on a standardized periapical radiograph using the long-cone technique, clinicians can determine whether the patient shows bone levels above or below the implant platform. Simple calculations are made between consecutive years to determine bone remodeling. After, the threshold value is attributed for each interval and a color code message (blue, yellow, green, and red) is applied. In this way, the patient can concentrate on color meanings and have an overall comprehension of the outcomes and how to improve their oral hygiene home-care measures. Although the validity of this new tool has not been scientifically investigated, it launches new perspectives on patient motivation for implant treatment.


Assuntos
Humanos , Implantação Dentária , Pacientes
16.
ImplantNews ; 10(3): 317-322, 2013. ilus, tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-681592

RESUMO

As técnicas existentes para posicionamento do implante zigomático geram variações no contato final osso/implante. Entretanto, clinicamente, não se sabe como isto afeta os valores de sobrevivência. O objetivo deste estudo foi verificar se diferentes modelos biomecânicos afetam os valores de dobramento em implantes zigomáticos não osseointegrados. Assim, duas investigações independentes foram realizadas; 60 implantes zigomáticos de 55 mm de comprimento foram utilizados. Na primeira etapa (M; n = 30), os implantes foram fixados em uma interface metálica. Na segunda etapa (B; n = 30), os implantes foram fixados em osso bovino congelado em temperatura controlada e retirados pouco antes do ensaio. Em cada etapa, as porções apicais dos implantes foram inseridas 8 mm, 10 mm e 12 mm nos blocos de fixação. Os implantes foram montados em 45 graus e submetidos à carga axial até deformação. Os valores máximos de dobramento foram registrados em quilogramas-força e o deslocamento em milímetros. Dentro de cada fase, os dados foram comparados pela análise de variância. O teste t Student foi usado para comparações entre as fases (nas respectivas profundidades de inserção). O nível de significância foi 5%. Na primeira etapa, as diferenças foram significativas apenas entre os grupos M8 e M12 (Anova um critério; p = 0,013). Entretanto, na segunda etapa, a comparação da força máxima entre os grupos não resultou em diferenças estatisticamente significantes. Os valores médios de dobramento nos grupos M foram estatisticamente maiores do que nos grupos B (p < 0,05). Pôde-se concluir que: a) nos modelos M, a resposta mecânica é melhor para implantes com 10 mm de inserção ou mais; b) o modelo biomecânico escolhido altera os valores de resistência ao dobramento.


Current techniques for zygoma dental implant placement can generate different bone-to-implant contact configurations. However, their influence on clinical survival rates is unknown. The aim of this study was to verify the influence of different biomechanical models on bending values for non-osseointegrated zygomatic fixtures. For this, two independent investigations were performed. Sixty 55 mm implants were used. In the first phase (M) (n=30), all implants were secured with a metallic interface. In the second phase (B) (n=30), implants were installed into fresh-frozen bone under controlled temperature conditions just before final test. Three insertion implant depths (8 mm, 10 mm, and 12 mm) were chosen. After, the implants were mounted in a 45-degree inclination and submitted to axial loading at the coronal portion until deformation. Maximum bending strength values were registered in kilograms-force and displacement in millimeters. The analysis of variance test was used to compare data among groups (within each phase). Also, a Student´s t test was performed to compare data between M and B depths. The level of significance was 5%. Significant differences were observed between M8 and M12 (one-way Anova; p = 0,013). However, no significant differences were among B groups. Bending values found in M were statistically higher than in B (p < 0,05). It can be concluded that: 1) In the M phase, the mechanical response is better for 10mm insertion depths or higher, and 2) the biomechanical model influences on the final strength values


Assuntos
Implantes Dentários , Teste de Materiais , Fenômenos Biomecânicos
17.
ImplantNews ; 9(5): 663-666, 2012. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-730036

RESUMO

Radiografias periapicais padronizadas pela técnica cone longo são necessárias para verificação dos níveis ósseos ao longo do tempo, principalmente no controle de pacientes com implantes osseointegrados. Este trabalho apresenta um método simples para padronização do posicionamento das radiografias, usando-se um dispositivo acrílico destacável e individualizável que pode ser colocado e retirado em qualquer momento. Desta forma, não é preciso comprar um posicionador radiográfico para cada paciente.


Periapical standardized radiographs with the long cone technique are necessary to verify bone levels over time, particularly for patients with osseointegrated dental implants. This report presents a simple method to standardize radiographs with an acrylic, detachable, customized device that can be removed and/or inserted at any time. In this way, it is not necessary to buy a film holder for each patient


Assuntos
Remodelação Óssea , Implantes Dentários
18.
Stomatos ; 17(33): 51-59, Jul.-Dec. 2011. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-693957

RESUMO

The objective of this study was to evaluate the retentive ability and weight change of two extracoronal attachments after repeated insertion/removal cycles. Material and methods: Two extracoronal attachments were used, one with plastic inserts and the other one with conventional metal-alloy. Initial retentive ability was checked under a 20kgf load cell at 5mm/min. The weight of the fixed/removable pairs was verified with an electronic mass comparator. Fixed/removable pairs were tested with an insertion/removal cycling machine, for 5800 cycles (corresponding to 5 years) at a speed of 32 rpm speed. Insertion/ removal cycles were performed under artificial saliva. Weight change and retentive ability of attachments were verified at baseline, six-month, one-year, two-year, three-year, four-year and five-year time intervals. The two-way ANOVA for repeated measurements test was used to verify possible interactions between precision attachment type and retentive ability/weight change over time. Statistically significant associations were found between attachment type and retentive ability over time (P=0.006). Metal-alloy group showed signifi cant differences between baseline and first year (P=0.005), baseline and second year (P=0.001), and between baseline and five years (P=0.035) of insertion/removal cycles. In the plastic insert group, no significant differences were found over time. No statistically significant associations were found between precision attachment types and weight change over time (P=0.643). Initial retentive ability can not be standardized for both attachments; the metal-alloy showed better performance than the plastic insert after five years. Both attachments did not show weight change after five years of simulated use.


O objetivo deste estudo foi avaliar a capacidade retentiva e a alteração do peso de dois encaixes extracoronários após repetidos ciclos de inserção e remoção. Materiais e métodos: Dois encaixes extracoronários foram usados, um com fêmea em plástico e o outro em metal. A capacidade retentiva inicial foi verificada em uma máquina de ensaio universal com célula de carga de 20kgf a velocidade de 5mm/min. O peso do conjunto macho/fêmea foi verificado com uma balança eletrônica. Os conjuntos macho/fêmeas foram testados em um simulador de ciclos por 5800 vezes (correspondendo a 5 anos) a uma velocidade de 32 rpm. Os ciclos de remoção e inserção foram realizados com saliva artificial. A alteração de peso e a capacidade retentiva dos encaixes foi verificada inicialmente e nos intervalos de tempo de 6 meses, um, dois, três, quarto e cinco anos. O teste ANOVA foi usado para verificar possíveis interações entre o tipo de encaixe e a capacidade retentiva/alteração de peso com o tempo de uso. Associação estatisticamente significativa foi encontrada entre o tipo de encaixe e a capacidade retentiva com o tempo de uso (P=0.006). O grupo metálico mostrou diferença significante entre o tempo inicial e o primeiro ano (P=0.005), tempo inicial e o segundo ano (P=0.001), e entre o tempo inicial e cinco anos (P=0.035) de inserção e remoção. No grupo com fêmea de plástico, não foram encontradas diferenças significativas. Associações estatisticamente significativas não foram encontradas entre os tipos de encaixes e a alteração de peso em tempo algum. (P=0.643). A capacidade retentiva inicial não pode ser padronizada nos dois encaixes; o grupo com fêmea em metal mostrou melhor performance retentiva que o grupo com fêmea em plástico após cinco anos. Ambos encaixes não mostraram alteração no peso após uso simulado de cinco anos.


Assuntos
Encaixe de Precisão de Dentadura , Materiais Dentários , Prótese Dentária , Retenção de Dentadura , Teste de Materiais
19.
J Prosthodont ; 19(6): 449-57, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20546490

RESUMO

PURPOSE: The purpose of this review was to highlight anatomic and biomechanical aspects of atrophic maxillae for implant possibilities. MATERIALS AND METHODS: A MEDLINE electronic search of the years 1966 to 2009 was conducted with the keywords "atrophic,""resorbed,""edentulous," and "maxilla." RESULTS: Twenty papers presented the following findings: (1) previous use of a removable prosthesis is a risk factor for resorption, with flabby tissues related to the severity of resorption; (2) implants in the reconstructed maxilla (< or =5 mm) and supporting overdentures had a higher risk for bone loss based on the worse periimplant soft-tissue health observed; (3) bleeding on probing was found with pocket depths > or =5 mm in half of the zygomatic implants; (4) prevalence of bone septa is higher in atrophic maxillae, and changes on nasopalatine canal can reduce up to 44.4% of the full length of buccal bone plates; (5) female patients have less medullar bone quantity and connectivity than male patients; (6) transectioning of nutrient vessels is easier and accelerates resorption; (7) stress does not concentrate on maxillary sinus base cortical bone contiguous to trabecular bone; (8) splinted implants receive nine times less load than nonsplinted implants even under oblique loading; (9) implant stability quotient (ISQ) values for implants ranged between 60 and 65; (10) in vivo force transfer to implants is similar between fixed prostheses and overdentures; (11) inclined implants generate better biomechanical responses; (12) masticatory efficiency and bite forces improve in maxillectomized patients who receive obturators with milled bar attachments. CONCLUSION: Sound implant-supported choices for an atrophic maxilla must be made with a thorough understanding of its anatomic and biomechanical factors.


Assuntos
Implantes Dentários , Maxila/patologia , Atrofia , Fenômenos Biomecânicos , Reabsorção Óssea/patologia , Reabsorção Óssea/fisiopatologia , Feminino , Humanos , Masculino , Maxila/fisiopatologia , Doenças Maxilares/patologia , Doenças Maxilares/fisiopatologia , Estresse Mecânico
20.
ImplantNews ; 7(3): 371-378, 2010. ilus, tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-563041

RESUMO

O objetivo deste trabalho foi verificar a precisão da técnica de cirurgia guiada e sem retalho, comparando os desvios angulares e lineares dos implantes cone-morse antes e depois da cirurgia, baseado em cortes tomográficos gerados em um ambiente tridimensional virtual computadorizado. Cinco pacientes com maxilas totalmente edêntulas foram utilizados neste estudo piloto. Após o planejamento reverso para montagem dos dentes e confecção do guia tomográfico, TCs foram obtidas com cortes de 0,2 mm de espessura, e as imagens geradas no software Dental Slice (Bioparts) para posicionamento dos implantes cone-morse Titamax EX (3,5-3,75 mm de diâmetro; Neoguide, Neodent). Após a cirurgia, novas TCs foram realizadas de acordo com o mesmo protocolo e inseridas no software. O desvio angular médio foi 2,033 ± 0,782º; a diferença linear na posição da plataforma, terço médio e apical foi 1,082 ± 0,907 mm, 1,599 ± 1,22 mm e 2,542 ± 2,047 mm, respectivamente. Todas as próteses com infraestrutura metálica e recobrimento de resina acrílica foram instaladas após 48 horas e os ajustes oclusais depois de 72 horas. Nenhuma complicação foi vista clinicamente, e as próteses e implantes permaneceram em função. Dentro dos limites deste estudo, os resultados demonstraram que a técnica é segura e precisa para ser utilizada nos consultórios. Entretanto, estes valores devem ser confirmados por estudos posteriores.


The aim of this study was to evaluate the precision of flapless, guided-surgery comparing angular and linear deviations of cone-morse dental implants before and after surgical procedures through CT slices generated on a computerized three-dimensional virtual environment. Five completely edentulous patients were enrolled in this pilot study. After reverse planning for tooth set-up and tomographic guide fabrication, CTs were made 0,2mm thick with images generated on Dental Slice (Bioparts) for placement of Titamax EX cone-morse implants (Neoguide, Neodent; 3.5-3.75mm in diameter). After implant placement, new CTs were made following the same protocol and transferred to Dental Slice software. Mean angular deviation values were of 2.033 ± 0.782º; registered linear differences at implant platform, middle and apical thirds were 1.082 ± 0.907mm, 1.599 ± 1.22mm, and 2.542 ± 2.047mm, respectively. All acrylic-veneered, metal-reinforced definitive prostheses were installed after 48 hours and occlusal adjustments provided after 72 hours. No clinical complications were seen, with all implants and prostheses remaining into function. Within the limits of this study, the results showed that this technique is safe and accurate for routine dental practice. However, these values must be confirmed in further studies.


Assuntos
Humanos , Masculino , Feminino , Adulto , Implantação Dentária Endóssea , Prótese Dentária Fixada por Implante , Arcada Edêntula , Cirurgia Assistida por Computador , Reabilitação Bucal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...